A home in Chesterfield had a radon reading of 434 Bq/m³, more than twice the UKHSA Action Level. We installed a positive input ventilation (PIV) unit set up for radon, and the follow-up reading is now below 30 Bq/m³.
A radon test at this Chesterfield house came back at 434 Bq/m³. UKHSA advises reducing radon in any home where the annual average is 200 Bq/m³ or more, so this level needed fixing.
Not every radon problem needs a sump. Positive input ventilation can work well where levels are moderately raised and the house is reasonably well sealed. A PIV unit in the loft draws in fresh air, filters it and feeds it gently into the home through a ceiling diffuser. This slightly pressurises the house, so less radon is drawn up from the ground, and it dilutes what does get in.
We fitted the PIV unit in the loft with a G4 filter on the intake, ran the ducting to a ceiling diffuser, and commissioned it with the unit's radon setting enabled. Getting the setup right matters: a PIV unit on the wrong setting won't move enough air to bring radon down.
The follow-up reading is now below 30 Bq/m³, down from 434 Bq/m³. That's well under the Action Level and close to the UK average for homes, with the added benefit of fresher air and less condensation.
The PIV unit in the loft, with its G4 intake filter and ducting down to the ceiling diffuser.