A home in the Hope Valley in the Peak District had radon readings of over 900 Bq/m³, more than four times the UKHSA Action Level. After we installed an active radon sump, the follow-up reading was 0 Bq/m³.
The Hope Valley sits in one of the higher-radon parts of England. A radon test at this house came back at over 900 Bq/m³. UKHSA advises reducing radon in any home where the annual average is 200 Bq/m³ or more, so this level needed fixing.
We fitted an active radon sump, installed from outside so there was no disruption inside the home. Using a wall-anchored, water-fed diamond core rig, we drilled at an angle through the external wall below floor level to reach the ground beneath the house and form the sump. Pipework runs from the sump up the gable wall to a radon fan, which draws the gas from under the floor and discharges it into the open air above.
The follow-up reading after installation was 0 Bq/m³, down from over 900 Bq/m³. The household now lives well below the Action Level.
The finished system: sump pipework rising up the gable wall to the radon fan and discharge.